Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review

Kamarul Amin, Abdullah@Abu Bakar and Mark F, McEntee and Warren M, Reed (2016) Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review. Journal of Medical Imaging and Radiation Oncology, 60 (4). pp. 459-468. ISSN 17549477

[img] Image
FH02-FSK-16-06110.jpg
Restricted to Registered users only

Download (178kB) | Request a copy
[img] Image
FH02-FSK-16-06462.jpg
Restricted to Registered users only

Download (203kB) | Request a copy
[img] Image
FH02-FSK-16-07690.jpg
Restricted to Registered users only

Download (159kB) | Request a copy

Abstract

The aim of this systematic review is to evaluate the radiation dose reduction achieved using iterative reconstruction (IR) compared to filtered back projection (FBP) in coronary CT angiography (CCTA) and assess the impact on diagnostic image quality. A systematic search of seven electronic databases was performed to identify all studies using a developed keywords strategy. A total of 14 studies met the criteria and were included in a review analysis. The results showed that there was a significant reduction in radiation dose when using IR compared to FBP (P < 0.05). The mean and standard deviation (SD) difference of CTDIvol and dose-length-product (DLP) were 14.70 ± 6.87 mGy and 186 ± 120 mGy.cm respectively. The mean ± SD difference of effective dose (ED ) was 2.9 ± 1.7 mSv with the range from 1.0 to 5.0 mSv. The assessment of diagnostic image quality showed no significant difference (P > 0.05). The mean ± SD difference of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were 1.05 ± 1.29 HU, 0.88 ± 0.56 and 0.63 ± 1.83 respectively. The mean ± SD percentages of overall image quality scores were 71.79 ± 12.29% (FBP) and 67.31 ± 22.96% (IR). The mean ± SD percentages of coronary segment analysis were 95.43 ± 2.57% (FBP) and 97.19 ± 2.62% (IR). In conclusion, this review analysis shows that CCTA with the use of IR leads to a significant reduction in radiation dose as compared to the use of FBP. Diagnostic image quality of IR at reduced dose (30-41%) is comparable to FBP at standard dose in the diagnosis of CAD.

Item Type: Article
Uncontrolled Keywords: coronary CT angiography; coronary artery disease; dose reduction; filtered back projection; iterative reconstruction.
Subjects: Q Science > QC Physics
R Medicine > R Medicine (General)
Divisions: Faculty of Health Sciences
Depositing User: Syahmi Manaf
Date Deposited: 13 Sep 2022 05:28
Last Modified: 13 Sep 2022 05:28
URI: http://eprints.unisza.edu.my/id/eprint/7425

Actions (login required)

View Item View Item